Revision history for KeyPgTo


Revision [21159]

Last edited on 2016-03-13 11:23:49 by fxm [Formatting]
Additions:





Revision [20557]

Edited on 2016-02-10 16:09:39 by DkLwikki [Update link format]
Additions:
[[KeyPgFor|For]] //iterator// //intial_value// **To** //ending_value//
[[KeyPgNext|Next]] [ //iterator// ]
[[KeyPgSelectcase|Select Case]] //case_comparison_value//
[[KeyPgCase|Case]] //lower_bound// **To** //upper_bound//
[[KeyPgDim|Dim]] //variable_identifier//( //lower_bound// **To** //upper_bound// ) [[KeyPgAs|As]] //type_specifier//
The ##**To**## keyword is used to define a certain numerical range. This keyword is valid only if used with ##[[KeyPgFornext|For ... Next]]##, ##[[KeyPgCase|Case]]## and ##[[KeyPgDim|Dim]]## statements.
In the first syntax, the ##**To**## keyword defines the initial and ending values of the iterator in a ##[[KeyPgFor|For]]## statement.
In the second syntax, the ##**To**## keyword defines lower and upper bounds for ##[[KeyPgCase|Case]]## comparisons.
In the third syntax, the ##**To**## keyword defines the array bounds in a ##[[KeyPgDim|Dim]]## statement
For more information, see ##[[KeyPgFornext|For...Next]]##, ##[[KeyPgDim|Dim]]## and ##[[KeyPgSelectcase|Select Case]]##.
Color 11
Print "Temperature" ; it ; " is in the low danger zone at" ; array( it ) ; " degrees!"
Color 14
Print "Temperature" ; it ; " is in the medium danger zone at" ; array( it ) ; " degrees!"
Color 12
Print "Temperature" ; it ; " is in the high danger zone at" ; array( it ) ; " degrees!"
Color 3
Print "Temperature" ; it ; " is safe at" ; array( it ) ; " degrees."
- ##[[KeyPgFornext|For...Next]]##
- ##[[KeyPgDim|Dim]]##
- ##[[KeyPgSelectcase|Select Case]]##
Deletions:
[[KeyPgFor For]] //iterator// //intial_value// **To** //ending_value//
[[KeyPgNext Next]] [ //iterator// ]
[[KeyPgSelectcase Select Case]] //case_comparison_value//
[[KeyPgCase Case]] //lower_bound// **To** //upper_bound//
[[KeyPgDim Dim]] //variable_identifier//( //lower_bound// **To** //upper_bound// ) [[KeyPgAs As]] //type_specifier//
The ##**To**## keyword is used to define a certain numerical range. This keyword is valid only if used with ##[[KeyPgFornext For ... Next]]##, ##[[KeyPgCase Case]]## and ##[[KeyPgDim Dim]]## statements.
In the first syntax, the ##**To**## keyword defines the initial and ending values of the iterator in a ##[[KeyPgFor For]]## statement.
In the second syntax, the ##**To**## keyword defines lower and upper bounds for ##[[KeyPgCase Case]]## comparisons.
In the third syntax, the ##**To**## keyword defines the array bounds in a ##[[KeyPgDim Dim]]## statement
For more information, see ##[[KeyPgFornext For...Next]]##, ##[[KeyPgDim Dim]]## and ##[[KeyPgSelectcase Select Case]]##.
Color 11
Print "Temperature" ; it ; " is in the low danger zone at" ; array( it ) ; " degrees!"
Color 14
Print "Temperature" ; it ; " is in the medium danger zone at" ; array( it ) ; " degrees!"
Color 12
Print "Temperature" ; it ; " is in the high danger zone at" ; array( it ) ; " degrees!"
Color 3
Print "Temperature" ; it ; " is safe at" ; array( it ) ; " degrees."
- ##[[KeyPgFornext For...Next]]##
- ##[[KeyPgDim Dim]]##
- ##[[KeyPgSelectcase Select Case]]##


Revision [15957]

Edited on 2012-02-02 12:26:19 by CountingPine [DIM->Dim]
Additions:
In the third syntax, the ##**To**## keyword defines the array bounds in a ##[[KeyPgDim Dim]]## statement
Deletions:
In the third syntax, the ##**To**## keyword defines the array bounds in a ##[[KeyPgDim DIM]]## statement


Revision [15571]

Edited on 2011-12-18 23:29:04 by CountingPine [Formatting]
Additions:
[[KeyPgFor For]] //iterator// //intial_value// **To** //ending_value//
[[KeyPgNext Next]] [ //iterator// ]
[[KeyPgSelectcase Select Case]] //case_comparison_value//
[[KeyPgCase Case]] //lower_bound// **To** //upper_bound//
**End Select**
[[KeyPgDim Dim]] //variable_identifier//( //lower_bound// **To** //upper_bound// ) [[KeyPgAs As]] //type_specifier//
The ##**To**## keyword is used to define a certain numerical range. This keyword is valid only if used with ##[[KeyPgFornext For ... Next]]##, ##[[KeyPgCase Case]]## and ##[[KeyPgDim Dim]]## statements.
In the first syntax, the ##**To**## keyword defines the initial and ending values of the iterator in a ##[[KeyPgFor For]]## statement.
In the second syntax, the ##**To**## keyword defines lower and upper bounds for ##[[KeyPgCase Case]]## comparisons.
In the third syntax, the ##**To**## keyword defines the array bounds in a ##[[KeyPgDim DIM]]## statement
For more information, see ##[[KeyPgFornext For...Next]]##, ##[[KeyPgDim Dim]]## and ##[[KeyPgSelectcase Select Case]]##.
Deletions:
FOR //iterator// //intial_value// TO //ending_value//
NEXT [ //iterator// ]
SELECT CASE //case_comparison_value//
CASE //lower_bound// TO //upper_bound//
END SELECT
DIM //variable_identifier//( //lower_bound// TO //upper_bound// ) AS //type_specifier//
The TO keyword is used to define a certain numerical range. This keyword is valid only if used with [[KeyPgFornext FOR ... NEXT]], [[KeyPgSelectcase SELECT / CASE]] and [[KeyPgDim DIM]] statements.
In the first syntax, the TO keyword defines the initial and ending values of the iterator in a FOR statement.
In the second syntax, the TO keyword defines lower and upper bounds for CASE comparisons.
In the third syntax, the TO keyword defines the array bounds in a DIM statement
For more information, see [[KeyPgFornext FOR...NEXT]], [[KeyPgDim DIM]] and [[KeyPgSelectcase SELECT CASE]].


Revision [12095]

The oldest known version of this page was created on 2008-01-04 10:01:04 by ElSairon [Formatting]
Valid XHTML :: Valid CSS: :: Powered by WikkaWiki



sf.net phatcode